About YSM Flame Retardant Reflective Tape
2024-02-23
YSM
YSMLITE
Fire retardant reflective tape is a functional tape that combines high-brightness reflective material with flame retardant substrate. It can not only improve visibility at night or in low light conditions, but also has excellent flame retardant properties. It is widely used in firefighting uniforms, rescue equipment, traffic facilities and industrial safety signs. Its dual advantages allow users to pursue safety and protection without worrying about spontaneous combustion or spread of materials in the event of an accidental fire.
The flame retardant reflective tape includes a flame retardant cloth base layer, which is characterized in that the flame-retardant cloth base layer is sequentially covered from bottom to top with an adhesive layer, an aluminum reflective layer, and a high refractive index glass bead layer, in which each glass bead has some spheres embedded in it. Inside the aluminum reflective layer.
Reflective clothing made of flame-retardant reflective tape has eye-catching retroreflective properties when exposed to weak light in low visibility conditions. When used as a fire fighting suit or a life saving suit, as long as there is a weak light, the search target can be found, which is beneficial to the rescue of firefighters or people wearing this kind of life-saving suit.

Indicators and descriptions of flame retardant reflective tape?
To understand flame retardant reflective tape, you must first master its core indicators. The following are the main performance parameters and their significance:
- Reflective coefficient: measures the brightness of the tape under the illumination of night light sources, generally in cd/(lx·m²), ≥ 150 cd/(lx·m²) is a common industrial-grade requirement.
- Flame retardant grade: According to the UL94 standard, it can be divided into V-0, V-1, and V-2 grades, of which V-0 means the fastest self-extinguishing and dripping without ignition.
- Temperature range: usually -40℃ to 120℃, meeting the requirements of attachment and durability in extreme environments.
- Tensile strength and tear strength: determine the stability of the tape after construction, generally tensile strength ≥ 20 N/25mm, tear strength ≥ 5 N.
- Weather resistance: UV resistance and resistance to humidity and heat cycles, ensuring long-term outdoor use without fading or cracking.
These indicators jointly determine the safety and reliability of flame-retardant reflective tape in practical applications, allowing users to select according to needs and quickly test on site.
What are the standards and requirements for flame-retardant reflective tape?
The production and use of flame-retardant reflective tape must comply with relevant national and industry standards to ensure product safety and compliance:
- EN ISO 20471:2020 High-visibility warning clothing standard requires reflective material brightness and coverage area.
- ANSI/ISEA 107:2015 US high-visibility safety clothing standard refines the width and layout of reflective tape.
- UL94 V-0: Flame retardant test to ensure that the material self-extinguishes within 10 seconds after the fire is extinguished and does not drip burning materials.
Production and testing in accordance with the above standards not only improve product trust, but also meet regulatory requirements in the fields of fire protection, transportation, and construction.
Production process and tools for flame-retardant reflective tape
If you want to use flame-retardant reflective tape in small batches or personalized projects, you can try the following steps:
Tool preparation
- Cutting tool: precision utility knife or carving knife
- Laminating equipment: household iron or hand-held hot air blower (temperature controllable).
- Anti-adhesive backing paper: protect the reflective surface from scratches.
Operation process
- Clean the surface of the substrate to ensure dust and oil-free.
- Cut the tape as needed, leaving a margin of 2-3 mm.
- Adjust the iron temperature to 140-160℃, wrap the tape with anti-adhesive paper, and heat it evenly.
- Remove the backing paper after cooling and check the bonding strength.
Professional production method
- In factory production, the following professional equipment and processes are usually used:
- Precision coating machine: control the thickness of the flame retardant adhesive layer to achieve ±5μm level accuracy.
- Automatic cutting machine: high-speed, high-precision slitting to meet the size consistency in large quantities.
- Continuous laminating line: constant temperature and pressure to ensure the adhesion and reflective performance of each meter of tape.
Whether it is DIY or professional production, temperature, pressure and time must be strictly controlled to avoid affecting the performance of the reflective film and flame retardant layer.

Application scenarios and selection of flame-retardant reflective tape?
Different scenarios have different demands for flame-retardant reflective tape. You can refer to the following suggestions when selecting:
Fire suits and rescue equipment
- Require reflective brightness ≥ 200 cd/(lx·m²), flame retardant grade V-0.
- It is recommended to use high heat resistance and chemical corrosion resistance products.
Traffic warning signs
- Require all-weather weather resistance, reflective tape width ≥ 50 mm.
- Recommended outdoor grade UV-resistant version, service life can reach more than 5 years.
Industrial safety zoning
- Ground and equipment warning lines: Self-adhesive flame-retardant reflective tape can be selected for quick construction and replacement.
- Indoor pipe and cable markings: You can choose more flexible products to fit curved surfaces.
When purchasing, please refer to the above application cases for quick decision-making based on the specific environment, life requirements and construction conditions.
Storage and maintenance of flame-retardant reflective tape?
Proper storage and maintenance can keep the flame-retardant reflective tape in the best condition and extend its service life:
Storage environment
- Temperature: 10℃–30℃; Relative humidity: 40%–60%.
- Avoid direct sunlight and high temperature and humidity, and place it in a dry and ventilated place.
Maintenance points
- Do not contact with organic solvents, acid and alkali liquids to prevent chemical corrosion.
- Check the sample roll regularly, use or replace it in time to avoid long-term indentation or deformation.
- When cleaning, wipe it gently with a soft cloth, and avoid using volatile solvents such as alcohol or gasoline.
Through the above measures, you can ensure that the performance of the tape is stable before and after use, and the effect will not be affected by improper storage.
As a manufacturer of fire retardant reflective tapes, YSM provides a variety of high-quality flame-retardant reflective tapes that meet various world standards, and provides one-stop service and free samples. Thank you and welcome to contact us!
Related News
Top flame retardant reflective tape Custom Wholesale Suppliers
2026-08-21
FR Reflective Tape:Fire Resistant and High Visibility
2026-08-19
Custom Glow in the Dark Film Factory
2026-08-17